TB 1-1730-229-30-03
_____ b. Place AC POWER switch to ON.
_____ c.
Verify the 400 Hz AC voltage at each of the 4 AC outlets. Measure and record the AC
voltage with a suitable voltage meter.
_______VAC
4.5.10 Battery Charger/Battery Charger Selector Switch Test.
_____ a. Set Battery charger selector switch to the following positions. Observe and record voltages
as read on the AGPU BATTERY meter.
Selector Position
Specification Voltage
Actual Voltage
28.5 VDC
26 to 31 VDC
____________
30.5 VDC
28 to 33 VDC
____________
32.5 VDC
29.5 to 34.5 VDC
____________
_____ b. Set battery charger selector switch to 28.5 VDC.
4.5.11 Battery Charger/Circuit Breaker Test.
_____ a. Open 35 A circuit breaker and observe that the CHGR/BATT fault light illuminates and the
engine does not shut down. Close 35A circuit breaker.
____
5.0
POST TEST
5.1
SYSTEM SHUTDOWN.
_____ a. Read and record the engine time hour meter and the number of starts during the test.
Transfer the data to the Equipment/Engine LOG BOOK.
_____ b. Disconnect all hoses Stow all hoses and cables.
_____ c.
Remove the roof and check the torque an all 1.0 and 2.5 inch hose clamps. Torque to 60-
inch pounds. Reinstall the roof.
_____ d. Disconnect large battery cable quick disconnect, but do not disconnect the tow alarm
connector.
34