URGENT
* T B 1-1520-240-20-96
DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
ONE TIME VISUAL INSPECTION AND
REPLACEMENT OF CERTAIN P/N 4C3074
CRISSAIR, INC.,CHECK VALVE
INSTALLED IN POWER CONTROL
MODULE ASSEMBLIES IN THE PORT
MARKED "FLT CONT PUMP" ONLY
FOR
ALL CH-47D, MH-47D, AND MH-47E AIRCRAFT
Headquarters, Department of the Army, Washington, D. C.
27 MARCH 1997
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
NOTE
THIS PUBLICATION IS EFFECTIVE UNTIL RESCINDED OR SUPERSEDED.
1.
Priority Classification. Urgent
a. Aircraft in Use. Upon receipt of this Technical Bulletin (TB) the condition status symbol of the cited
aircraft will be changed to a red horizontal dash "-". The red horizontal dash "-" may be cleared when
the inspection of paragraph 8 below is completed. The affected aircraft shall be inspected as soon as practical
but no later than the task/inspection suspense date. Failure to comply with the requirements of this TB within
the time frame will cause the status symbol to be upgraded to a red "X". Ninety days order, ship, and replace-
ment time is allowed once defective check valves are found. Pending availability, depots will replace defective
check valves prior to unit acceptance.
d. Aircraft in Transit.
e.
This TB supersedes USAATCOM Message 1315142 MAR 97 (CH-47-97-ASAM-04)
1