TB 1-1730-229-30-3
NOTE
ENGINE SHOULD NOT CRANK. If so, set START switch to STOP and
check all previous engine preparation steps.
______
(7) Hold START switch in RUN until fuel is present at the fuel control unit. (Use container
to catch fuel; will require about 5-10 seconds of pump operating.) Place START switch
to STOP.
______
(8) Reconnect flex fuel line to Fuel Control Valve.
______
(9) Remove stainless steel line from Fuel Solenoid input side.
______
(10) Operate AGPU fuel pump as described in Steps 5 and 6, above, until fuel flows into
container. Accumulate approximately 2 to 3 ounces. Flow shall be slow but consistent.
______
(11) Replace fuel lines and tighten.
______
(12) Ensure AGPU hydraulic reservoir selector is placed in the AGPU mode.
______
(13) Close the high pressure bypass valve.
______
(14) Open the hydraulic pressure gauge valve 1/4 turn.
______
(15) Place the bypass selector to BYPASS.
______
(16) Open the high pressure and return bleed valves 1-1/2 turns.
______
(17) Turn the high pressure relief valve in (to increase pressure) approximately two full turns.
______
(18) MASTER SWITCH to OFF.
WARNING
If any operation or indication appears abnormal during the following
procedures, set ENGINE CONTROL switch to STOP or press
EMERGENCY STOP or set MASTER SWITCH to OFF. Discontinue test
until problem is resolved.
CAUTION
If hydraulic pump and system has not been purged of air, DO NOT
START GTE until this operation is performed.
4.3
PRE-START PROCEDURE
______ a. Set all toggle switches to the OFF position.
______ b. Set MASTER SWITCH to ON.
______ c.
Depress PRESS TO TEST switch.
23