TB 1-2840-248-20-2
(e) Preparation Instructions For Completion of Copy 2 of a DA Form 2410 For Repair,
SECTION III--REPAIR/OVERHAUL/GAIN DATA. This section appears on the lower half of copy 2. Entries in
this section as well as block 36 of copy 3 are made by the organization that returns the item to a serviceable
condition. The same organization will also update blocks 6, 7, 8, 9, 10 and 13 by lining out existing entries and
providing the correct data.
Block 13. Component cumulative counts/hours. If the item entered in block 1 is a module, which has been
operated on a slave engine to ensure serviceability after repair, the component cumulative counts/hours must
be updated. Calculate the LCF-1, LCF-2, T/TI counts and operating hours accumulated by the module while
operating on the slave engine and add these counts/hours to the total cumulative counts entered in block 13.
Line out the existing figures in blocks 8 and 13 and enter the updated counts/hours in block 13 and time since
new in block 8 above the old figures. Ensure that line 1 of the DA Form 2408-16-1 for the module and blocks 8
and 13 of the DA Form 2410, Copy 3 are also updated at this time.
Block 32. Date checked. Enter the julian date that the action shown in block 36 was completed.
Block 33. Signature and telephone number. The person verifying the entries will sign this block and enter
their phone number (DSN/AUTOVON or commercial). The phone number provided can be used to clarify
entries.
Block 34. UIC (this action) . Enter the unit identification code of the organization that completed the action
shown in block 36. If a contractor enter your CAGE code prefixed with a "K".
Block 35. Manhours to repair/overhaul. Enter the total manhours in hours and tenths of an hour it took to
repair, overhaul, or rebuild the item. (See time conversion chart Table 1-13 in DA
Pamphlet 738-751 at the end of chapter 1 or as listed on the backside of DA Form 2408 (Equipment Log
Assembly).
Block 36. Inspection and action codes. If the item is found serviceable enter "A" in the small block next to
serv (serviceable). When an unserviceable item is returned to serviceable status enter D, E, F, or G in the
block that applies. Do not use check marks.
Block 37. Reason for gain. Leave this block blank since these instructions are for repair/overhaul only.
Block 38. Maint level. Enter the level of the maintenance unit performing the action indicated in block 36.
("0" for AVUM, "F" depot.)
Block 39. UIC (shipped to). Leave this block blank.
Block 40. Actual failure code. Block 10 of this form identifies the apparent failure code or reason for
removal code at removal time for the item listed. Upon further disassembly and repair,
13