SB 742-1
d.
Visual
Barrier bag missing or damaged to extent environmental
protection is compromised
e. Packaging damaged to extent that contents are not
Visual
adequately protected
f. Shelf life exceeded (20 years)
Visual
g. Venturi obstructed or foreign material present
Visual
3. Minor:
a. Packaging hardware damaged, missing, or inoperative
Visual/Manual
b. Packing loose, filler material inadequate or missing
Visual/Manual
c. Carrying strap damaged, deteriorated or missing
Visual/Manual
M-6. Inspection description and notes.
a. If accessible, inspection will verify serviceability of the
sight, hinge pin and spring.
b. Early production units were color coded with a black
band on the launch tube and marked with FSC 1340; later
production is marked with a yellow band on a black band on
launch tube and FSC 1315.
c. When component is damaged to the extent that
functional effectiveness has been degraded, condition will be
classified as a defect.
d. If the weapon is returned after removal from barrier
bag, a complete visual inspection will be performed.
If
otherwise serviceable, weapon will be designated for priority
issue. While barrier material is normally considered water and
vapor proof, material that comprises the M136 "flat bag" is not
vapor proof.
e. A rattling noise from fin assembly inside launch tube is
not a defect.
a. TM 9-1340-886-14.
b. TM 9-6920-886-14&P.
c. Drawing 13229861.
d. Drawing 13230240